Kestrel 5500 Environmental Meter, Olive Drab
DESCRIPTION
The Kestrel 5500 does it all – measures altitude, barometric pressure, crosswind, density altitude, dew point temperature, direction (wind direction and orientation), headwind/tailwind, heat stress index, relative humidity, station pressure (absolute pressure), temperature, wet bulb temperature (Psychrometric), wind chill, and wind speed. The Kestrel 5500 features a large, high contrast screen, dual color backlight, scratch- and breakage-resistant window, corrosion-resistant battery compartment with secure door, intuitive user-interface, plus it tracks and logs over 10,000 sets of time-stamped data. Data can be transferred to a PC/MAC with the optional waterproof USB Data Transfer Cable (sold separately). Combine the Kestrel 5500 with a portable vane mount and portable tripod (each sold separately) for a data-logging weather station that rotates in even the slightest breeze and is ideal for short-term monitoring. This versatile, waterproof instrument floats, features an easy-to-read backlit display, and has an auto shutdown feature which activates after 15 minutes without a button press (feature can be disabled). Lanyard, protective pouch, lithium AA battery (average life 400 hours), certificate of conformity, and instruction manual are included. Five-year manufacturers warranty.
SPECIFICATION
Brand:KestrelMPN:0855OLV
UPC:730650001989
UNSPSC:41114400
SENSORS Wind Speed/Air Flow Accuracy: Larger of 3% of reading, least significant digit or 20 ft/min. Resolution: 0.1 m/s; 1 ft/min; 0.1 km/h; 0.1 mph; 0.1 knots. Specification Range: 0.6 to 40.0 m/s; 118 to 7,874 ft/min; 2.2 to 144.0 km/h; 1.3 to 89.5 mph; 1.2 to 77.8 knots. Ambient Temperature Accuracy: 0.9 F; 0.5 C. Resolution: 0.1 F; 0.1 C. Specification Range: -20.0 to 158.0 F; -29.0 to 70.0 C. Relative Humidity Accuracy: 2%RH. Resolution: 0.1%RH. Specification Range: 10 to 90% 25C non-condensing. Pressure Accuracy: 1.5 mbar at 25C, 700-1100 mbar/ 0.044inHg at 77F 20.67- 32.48 inHg/ 0.022 PSI 10.15-15.95 PSI. Resolution: 0.01 inHg; 0.1 hPa/mbar; 0.01 PSI. Specification Range: 25C/77F; 700-1100 mbar; 20.67-32.48 inHg; 10.15 – 15.95 PSI. Compass Accuracy: 5. Resolution: 1; 1/16th Cardinal Scale. Specification Range: 0 to 360. CALCULATED MEASUREMENTS Air Density Accuracy:0.0002 lb/ft3; 0.0033 kg/m3.Resolution: 0.001 lbs/ft3; 0.001 kg/m3. Sensors Employed:Temperature, Relative Humidity, and Pressure. Air Flow Accuracy:6.71%. Resolution:1 cfm;1m3/hr 1m3/m 0.1m3/s 1 L/s. Sensors Employed:Air Flow,User Input (Duct Shape & Size). Altitude Accuracy:typical 23.6 ft/7.2 m, – 750 to 1100 mBar; max 48.2 ft/14.7 m 300 to 750 mBar. Resolution: 1 ft; 1m. Sensors Employed:Pressure,User Input (Reference Pressure). Barometric Pressure Accuracy:0.07 inHg; 2.4 hPa|mbar; 0.03 PSI. Resolution:0.01 inHg; 0.1 hPa|mbar; 0.01 PSI. Sensors Employed:Pressure,User Input (Reference Altitude). Crosswind & Headwind/ Tailwind Accuracy:7.1%. Resolution:1 mph;1 ft/min 0.1 km/h 0.1 m/s 0.1 knots. Sensors Employed:Wind Speed, Compass. Delta T Accuracy:3.2 F; 1.8 C. Resolution:0.1 F; 0.1 C. Sensors Employed:Temperature, Relative Humidity,Pressure. Density Altitude Accuracy: 226 ft; 69 m. Resolution:1 ft; 1m. Sensors Employed:Temperature, Relative Humidity,Pressure. Dew Point Accuracy:3.4 F;1.9 C;15-95% RH. Refer to Range for Temperature Sensor. Resolution:0.1 F; 0.1 C. Sensors Employed:Temperature, Relative Humidity. Evaporation Rate Accuracy:0.01 lb/ft2/hr; 0.06 kg/m2/hr. Resolution:0.01 b/ft2/hr; 0.01 kg/m2/hr. Sensors Employed:Wind Speed; Temperature Relative Humidity Pressure User Input (Concrete Temperature). Heat Index Accuracy:7.1F; 4.0C. Resolution:0.1 F; 0.1 C. Sensors Employed:Temperature, Relative Humidity. Moisture Content/Humidity Ratio (Grains) Accuracy:.3gpp .4g/kg. Resolution:0.1 gpp; 0.01 g/kg. Sensors Employed:Temperature, Relative Humidity, Pressure. Relative Air Density Accuracy:0.3%. Resolution:0.1%. Sensors Employed:Temperature, Relative Humidity, Pressure. Wet Bulb Temperature – Psychrometric Accuracy:3.2 F; 1.8 C. Resolution:0.1 F; 0.1 C. Sensors Employed:Temperature, Relative Humidity, Pressure. Wind Chill Accuracy:1.6 F; 0.9 C. Resolution:0.1 F; 0.1 C. Sensors Employed:Wind Speed, Temperature.
Reviews
There are no reviews yet.